Download PDFOpen PDF in browserMachine Learning-Based Polynomial Surrogate Model for Calibrating Effective Wall Slip in Microvessel Blood Flow Simulations14 pages•Published: November 24, 2026AbstractA polynomial surrogate model developed within a supervised machine learning framework is proposed for calibrating an effective slip boundary condition in finite-element models of blood flow in microvessels with diameters of 4 – 8 μm. Blood is represented as a two-phase fluid with spatially varying viscosity, and the wall-slip coefficient α is determined by matching the finite-element apparent viscosity to an empirical in vitro apparent-viscosity relation. The calibration was performed over a three-dimensional parameter space defined by the vessel radius, linear hematocrit, and cell-free-layer thickness. A finite viscosity-matching value of α was obtained for 105 of the 125 investigated geometries, whereas for 20 geometries the empirical target could not be reached even in the no-slip limit. The dimensionless slip parameter was represented by a cubic response surface, yielding R²=0.9998 and a five-fold cross-validated R²=0.9996. The resulting surrogate model provides an efficient representation of the calibrated boundary condition within the sampled feasible parameter domain.Keyphrases: blood flow in microvessels, in vitro data, machine learning, pde based blood flow simulation, stokes equations In: Varvara Turova, Andrey Kovtanyuk, Anna Maslovskaya and Johannes Zimmer (editors). Proceedings of the Workshop on Mathematical Modeling and Scientific Computing, vol 114, pages 101-114.
|