Tags:measuring and control complex, mobile power unit and rational operation mode
Abstract:
Research goals and objectives: to increase efficiency and safety of Mobile Power Unit operation mode using Information and Communication Technology and Measuring and Control Complex. Results of the research: The proposed algorithm made it possible to remove the worst mode, namely the overload mode, almost at the initial stage of analysis, and the nominal one dominates 1.5 times over the under load mode, both in volume and in terms of the ellipsoid nucleus specific weight. This suggests that the appli-cation of this algorithm is not inferior to the precision of the classical analysis method. The methodology for selecting a rational operation mode has been exper-imentally confirmed and can be used to optimally control the Mobile Power Unit in the operation region.
Selecting a Rational Operation Mode of Mobile Power Unit Using Measuring and Control Complex