![]() Title:Assessing the Integration of the Vertical Ventilation via Double Skin System with Cross Ventilation for Educational Spaces in Hot Arid: a Simulation Study Conference:TMREES26Lb Tags:Computational fluid dynamics (CFD), Double-skin façade (DSF) and Natural ventilation Abstract: This study investigates the combined performance of cross-ventilation and double-skin façade (DSF) in an existing STEM classroom in Borg El-Arab, Alexandria, Egypt through three-dimensional CFD simulation in Ansys fluent. Five facades configurations were evaluated bulk air-change rate (ACH), pressure distribution, and airflow in the occupied zone (z=1.10 m), for the same boundary conditions. Results revealed a mismatch between the ventilation rates and local airflow distribution. Although ACH for case 1 was the highest (26.58 h-1), 65.4% of the occupied-zone area was still below 0.10 m/s. Case 2 resulted in a 17.7 h-1 reduction of ACH with a 45.0% reduction of low-velocity area. DSF configurations, Case 3 had a balanced performance with ACH 24.05 h-1, highest mean occupied-zone velocity (0.136 m/s) and low-velocity area of 47.8%. Case 5 had low velocity area with 76.3% of the occupied zone under 0.10 m/s. Thus, opening arrangement and airflow pathways matter beyond ACH alone. Assessing the Integration of the Vertical Ventilation via Double Skin System with Cross Ventilation for Educational Spaces in Hot Arid: a Simulation Study ![]() Assessing the Integration of the Vertical Ventilation via Double Skin System with Cross Ventilation for Educational Spaces in Hot Arid: a Simulation Study | ||||
| Copyright © 2002 – 2026 EasyChair |